ETSO Deviation

Displaying 61 - 72 of 144

This list displays content that is tagged with ETSO Deviation

  • Extended title
    Deviate from RTCA DO-283A Appendix C section C.2.1 by using a different weighting-algorithm to select or exclude VOR stations, and secured with reasonableness checks.
    Closing date of consultation
    Consultation / Publication type
  • Extended title
    Deviates from RTCA DO-283A Appendix C section C.2.2 by using a different algorithm to determine position from multiple (more than two) DME, and secured with reasonableness checks.
    Closing date of consultation
    Consultation / Publication type
  • Extended title
    Deviates from RTCA DO-283A Appendix H section H.2.4.4.3 by using a different vertical guidance compatible of the vertical constraints.
    Closing date of consultation
    Consultation / Publication type
  • Extended title
    Deviates from RTCA DO-283A Appendix H section H.2.7 by alerting 15 seconds instead of the minimum 30 seconds before the required vertical path change.
    Closing date of consultation
    Consultation / Publication type
  • Extended title
    Deviate from RTCA/DO-229D 2.2.3.3.1 and provide the deviations relative to the first approach leg instead of the FAF.
    Closing date of consultation
    Consultation / Publication type
  • Extended title
    Clarification on the limited validity of equation (A-22) and (A-22a) proposed by DO-229(A,B,C,D) for the ionospheric pierce point location computation and provision of a formula which does not have that limitation.
    Closing date of consultation
    Consultation / Publication type
  • Extended title
    Deviate from ETSO‐C30c by not marking the minimum lamp candle power or lamp part number for lights using non‐replaceable light‐emitting component(s).
    Closing date of consultation
    Consultation / Publication type
  • Extended title
    Deviate from ETSO-C80, Appendix 1, § 4.2.a, substituting the test fuel MIL-S-3136, Type III, with fuel Jet A1 for tests in the paragraphs: §7 Slosh, §8 Stand test, §10 Fluid resistance of exterior surface, and §17 Low temperature leakage.
    Closing date of consultation
    Consultation / Publication type
  • Extended title
    Deviates from ETSO-C80, Appendix 1, § 7 Slosh test, specifically from § 7.1.15, performing slosh test without including water and dye in the test fluid as required by the test procedure.
    Closing date of consultation
    Consultation / Publication type
  • Extended title
    Deviate from ETSO-C80, Appendix 1, § 7.1.3 performing slosh test at room temperature instead of at 135°±10° F.
    Closing date of consultation
    Consultation / Publication type
  • Extended title
    Deviate from ETSO-C80, Appendix 1, § 11.0 Permeability, specifically from §11.1.2 Test Procedure, carrying out permeability testing at a relative humidity (RH) level of 50 +/- 5% instead of 40 +/- 5%.
    Closing date of consultation
    Consultation / Publication type
  • Extended title
    Deviate from ED‐73E by not performing explosion test for these equipment limited to installation in nonexplosive atmosphere.