CS ACNS.B.DLS.B1.030 Integrity
ED Decision 2013/031/R
The data link system integrity is designed commensurate with a ‘major’ failure condition.
CS ACNS.B.DLS.B1.035 DLS system continuity
ED Decision 2022/008/R
(See AMC1 ACNS.B.DLS.B1.035 and GM1 ACNS.B.DLS.B1.035)
The data link system is designed to provide a level of continuity that supports the intended operation.
[Issue: CS-ACNS/4]
AMC1 ACNS.B.DLS.B1.035 DLS system continuity
ED Decision 2022/008/R
The loss of the data link system function is considered to be a minor failure condition.
[Issue: CS-ACNS/4]
GM1 ACNS.B.DLS.B1.035 DLS system continuity
ED Decision 2022/008/R
The definition of continuity in CS-ACNS is different from the definition of continuity in EUROCAE ED‑120. Throughout CS-ACNS, continuity (system continuity) refers to ‘the probability that a system will perform its required function without unscheduled interruption’. In the context of ED-120, this would be commensurate with the term ‘availability’.